Black and white photograph of the cantilevered stair at The Opulence in New Alipore under construction
The cantilevered stair at The Opulence in New Alipore, photographed on site during construction. On site: The Opulence, New Alipore, Kolkata, by the studio.

The short answer

For a house, NBC 2016 allows a tread of at least 250 mm, a riser of up to 190 mm, a clear width of 1.0 m, headroom of 2.2 m and no more than 12 risers per flight. A comfortable stair keeps twice the riser plus the going between 530 and 630 mm. Flats need 1.25 m. Check the local rule on your plan.

For a house, NBC 2016 allows a tread of at least 250 mm, a riser of up to 190 mm, a clear width of 1.0 m, headroom of 2.2 m and no more than 12 risers in a flight. Flats need a 1.25 m stair. A comfortable stair is gentler than these limits, and your sanctioned plan follows the local rule.

What do the codes say about a stair?

The National Building Code of India 2016 gives the main figures, and the Kolkata rules add widths by building height. The table sets them side by side. The NBC figures were read on a public scan of the code, and the KMC figures on a legal-database transcription of the 2009 rules, so confirm both against the current text.

Item One or two family dwelling (NBC 2016) Other buildings (NBC 2016)
Tread, minimum 250 mm 300 mm
Riser, maximum 190 mm 150 mm
Clear width 1.00 m (0.75 m for two-storey row housing) 1.25 m for flats and similar; 1.50 m for hotels
Headroom 2.2 m 2.2 m
Risers per flight 12 at most 12 at most

The same clauses appear in Part 3 (clause 12.18) and Part 4 (clause 4.4.2.4.3) of the code. A newer BIS text, the National Building Construction Standards 2026 Part F, lowers the riser limit for one or two family dwellings to 175 mm. Part F describes itself as guidance for the state government or local authority, and the studio could not confirm which edition West Bengal applies. Draw to the lower figure where you can; it also makes a better stair.

On the Kolkata side, the 2009 rules set stair widths for residential buildings by height: 1.00 m above 7 m, 1.1 m with a larger landing above 10 m, and 1.25 m for taller buildings, and they allow a passage within an apartment of 1.0 m. The studio found no separate KMC riser or tread rule, and the rules defer to the National Building Code for matters they do not cover.

What proportions make a stair comfortable?

Keep twice the riser plus the going between 530 and 630 mm. IS 1634:1992, the Bureau of Indian Standards code for wood stairs in houses, gives the rule of thumb. It also asks for a going of at least 250 mm, a riser of at most 190 mm and a pitch of at most 37 degrees, and says winders should be avoided as far as practicable. The 2R plus G rule is empirical guidance, not an NBC clause.

A worked example with the studio’s own arithmetic, not from a code: for a floor-to-floor height of 3,000 mm, 17 risers give a riser of about 176 mm. With a going of 275 mm, twice the riser plus the going is about 627 mm, inside the range. That is two flights, say nine and eight risers, with a landing between. Your floor height and plan will change the numbers.

What types of stair are there?

Pick the type from the space you have, and from who will use it.

Type Suits Watch for
Straight Narrow plots with a long run Needs length; a long flight needs a landing
Dog-leg (two flights, turn at a landing) Most houses and flats A well in the middle, which can take a lift or a light shaft
L or quarter-turn Corners and double-height rooms The landing has to be wide enough to turn
U Tall floors More floor area than a dog-leg
Spiral Roof access, mezzanines The NBC accessibility annex says spiral stairs should be avoided
Cantilevered Open plans, a feature stair Needs a structural engineer; the treads depend on the wall that carries them

Avoid winders in the main stair. If you need one, IS 1634 says to put it at the bottom of the flight.

How high should the handrail be?

Between 850 and 950 mm above the stair, where the accessibility annex of NBC 2016 applies, with a second, lower handrail at 650 to 750 mm for children and shorter users. The annex also asks for a handrail that extends 300 mm beyond the first and last nosing and for a grip diameter of 38 to 45 mm. IS 1634 gives a sloping handrail height of not less than about 1.0 m from the pitch line, and the studio could not confirm that figure against the printed standard, so ask your engineer. The Harmonised Guidelines 2021, which apply to public and universal access, ask for handrails at two levels and for 200 lux of light on the flight. These are not residential requirements, but they set a good benchmark for a house with older people or children.

Gallery with a balustrade at the New Town banquet hall during construction
A gallery balustrade on site at the New Town hall. The edge of a stair or gallery needs a guard and a handrail. On site: Banquet hall, New Town, Kolkata, by the studio.

Where a stair or gallery has an open edge, add a guard rail of full height, as in the gallery photograph from the New Town hall site.

What finish is safe on a stair?

One that is not slippery. The NBC’s accessibility annex says slippery surfaces like granite and glazed tiles should be avoided on stairs, and the Harmonised Guidelines rate polished marble and granite as having very poor slip resistance when wet and polished. A honed or textured stone, a timber with a grip, or a tile with a non-slip finish is a safer choice. A contrasting strip at the tread edge helps the eye, and the Guidelines suggest a band of 50 mm for public stairs.

What does the studio’s cantilevered stair show?

The New Alipore apartment building, The Opulence, has a cantilevered stair, photographed here during construction. It carries inside the building the same clarity as the facade of vertical fins and layered balconies, according to the project page. The building is complete, and the stair is a built element, though this picture is from site. See The Opulence and the post on the G+4 apartment story.

A cantilevered stair is a structural design problem first. Each tread is fixed to a wall or a spine and carries the load without a stringer below, so the wall, the reinforcement and the fixing need an engineer’s drawings. The architect sets the proportions and the engineer proves them.

How do you use the space under a stair?

Plan it from the start. Under-stair space can hold a store, a wardrobe, a powder room or a shelf, but only where the headroom and the structure allow it. A powder room needs its own ventilation and drainage, so decide early. The post on duplex house design shows how the stair position shapes the rest of the plan.

What should you do next?

If you are planning a house or an apartment block, the studio’s architecture service covers the stair as part of the plan and the sanction drawings. The contact page has the studio’s phone, email and form.

Questions people ask

What is the standard riser and tread for a staircase in a house in India?

NBC 2016 Part 3 sets a standard tread of 300 mm and riser of 150 mm, and for a one or two family dwelling lets the tread fall to 250 mm and the riser rise to 190 mm.

What is the minimum width of a staircase in a house?

NBC 2016 asks for a clear width of 1.00 m for a one or two family private dwelling, 0.75 m for two-storey row housing and 1.25 m for flats and similar residential buildings. KMC rules set widths by building height.

How many steps can a flight have?

NBC 2016 limits a flight to 12 risers. A landing breaks a longer climb into flights.

What headroom does a staircase need?

The NBC text says the minimum clear headroom in any staircase is 2.2 m, measured vertically from the line of the nosings. Some web guides quote 2.1 m, but the code says 2.2 m.

Is a spiral staircase allowed in a house?

The NBC's accessibility annex says spiral stairs should be avoided. The annex is about accessible design, and a spiral stair is also steep and awkward for carrying furniture, so keep it for secondary access.

Work by the studio mentioned here

Sources

  1. National Building Code of India 2016, Part 3, clause 12.18 and Annex B; Part 4, clause 4.4.2.4.3, Bureau of Indian Standards (public scan on archive.org). Accessed 2026-11-13.
  2. IS 1634:1992 Design and construction of wood stairs for houses, code of practice, Bureau of Indian Standards. Accessed 2026-11-13.
  3. Kolkata Municipal Corporation Building Rules, 2009, rule 127, Kolkata Gazette, as reproduced on Indian Kanoon. Accessed 2026-11-13.
  4. Harmonised Guidelines and Standards for Universal Accessibility in India 2021, Ministry of Housing and Urban Affairs. Accessed 2026-11-13.
  5. National Building Construction Standards 2026, Part F (Fire and Life Safety), Bureau of Indian Standards (copy hosted by the Goa Directorate of Fire and Emergency Services). Accessed 2026-11-13.

Rules, fees and costs change. Figures are as published on the dates shown; check the current circular with the authority before you rely on them. This page is general information, not legal or financial advice.

Read next

  • Contemporary Indian house design: six moves rooted in local practice

    Six moves make a house look contemporary and work in India: a jaali screen, a verandah or deep chhajja, a courtyard or light well, brick left visible, openings set for cross-ventilation, and a raised plinth. Each is an old local answer to sun, rain or privacy, redrawn in today's materials.

    Design and styles,
  • Building a house in Kolkata while living abroad: POA, approvals, payments

    An NRI or OCI may buy non-agricultural property in India under RBI's Master Direction, and may be represented by an attorney under a power of attorney executed before a notary, magistrate or Indian consul and then stamped in West Bengal. Building authorities accept an authorised representative as applicant. Pay by stage against measured work.

    Guides,
  • Completion and occupancy certificate in Kolkata: who issues it and how

    In Kolkata Municipal Corporation limits the permission to occupy is called the Completion Certificate. Other West Bengal municipalities and NKDA call it the Occupancy Certificate. Each needs a notice within one month of completion, an inspection within 15 days, and a structural stability certificate signed by the engineer.

    Guides,
  • Soil test and foundation types for a house in Kolkata's soft soil

    Kolkata's ground is soft alluvial clay, so a soil investigation under IS 1892 comes before the foundation design. One New Town report found about 16 m of soft clay with the water table at 3.5 to 4.3 m. Small houses often take isolated footings or a raft, and heavier or taller ones take piles, as the geotechnical report decides.

    Guides,

All articlesMore in design and styles